Overfill Grounding Permissives
Manufacturer: civacon
RM140W monitor
Monitor for permissive grounding and overfill control, up to 12 compartments.
manufacturing
Liquip
Application
Bottom loading and top loading.
Features
- Explosion and moisture proof housing (meets NEMA 4 and 7);
- Self-Test system at startup and continuous Self-Monitoring, ensuring the safety of the operation;
- High resolution display visible even in direct sunlight;
- 2 SPDT Output Relays for independent Interlocking (grounding and overflow);
- Response time less than 0.5s;
- Supply voltage 110 / 240Vac (selectable during installation);
- Compact, functional design for easy installation;
- Red, blue and green indicator lights (led):
- Red - non-permissive (grounding and overfill sensor)
- Red and Blue - non-permissive (grounding) and permissive (overfill sensor)
- Green and Blue - permissive (grounding and overfill sensor)
- Series of 12 red lights (led) indicating the overfill sensor of each compartment of the tank truck:
- On - indicates in which compartments the overfill sensors are wet (alarm)
- Blinking - indicates the number of compartments that have not been identified (inactive overfill sensors)
- Off – indicates the number of bins that have been identified (overfill sensors active).
Certification
- IECEx, ATEX, FM and INMETRO (CSE).
Bottom Loading Accessories
- Aluminum Junction Box with 7-pin socket;
- Orange colored spiral cable with 10 sjo type conductors, 9M extended (1.5M compressed);
- 6-pin optical API plug in blue color for connection to the tank truck;
- (Optional item) Aluminum breakaway type plug for connection to junction box that allows cable disconnection, if over tensioned, preventing further damage.
Top Loading Accessories
- Aluminum junction box for interconnecting black coil cable and alligator clip;
- Coil cable in black color, with 5 conductors, 2M at rest and up to 12M stretched for connection to the junction box;
- Alligator claw made of aluminum for connection to the truck;
- Aluminum Junction Box with 7-pin socket for connection to the overfill sensor;
- Optical aluminum overfill sensor to be connected to the junction box to send feedback to the monitor in case of overfill detection.
Related Links
RM140 - Overfill & Grounding Monitor
8030 Monitor (120 or 240)
Monitor for permissive ground control.
manufacturing
civacon
Application
Top Loading Loading.
Features
- Uses the principle of continuous self-checking on all system components (self-checking)
- Mounted in an explosion-proof and weather-proof aluminum housing
- Response time 0.5 seconds
- Nema 4, FM approval and CSA certification for use in explosive atmosphere, Exd IIB GB, Extb IIIC Db, IP-67, 02
- Status lamps (green - permissive and red - non-permissive)
- It has a relay output with 02 SPDT contact channels, one normal open and one normal closed, 5a, 250vac - resistance
- 2 electrical connections of 3/4” NPT, power supply: 110v or 220v, 60hz.
Certification
- UL and INMETRO (CSE).
Accessories
- Aluminum junction box for interconnecting black coil cable and alligator clip;
- Coil cable in black color, with 5 conductors, 2M at rest and up to 12M stretched for connection to the junction box;
- Alligator claw made of aluminum for connection to the truck.
Related links
Civacon Model 8030 Ground Verification Monitor from OPW-ES
8130 Monitor (120 or 240)
Monitor for permissive grounding and overfill control, up to 8 compartments.
manufacturing
civacon
Application
Top Loading or Bottom Loading.
Features
- Uses the principle of continuous self-checking on all system components (self-checking)
- Mounted in an explosion-proof and weather-proof aluminum housing
- Response time 0.5 seconds
- Nema 4, FM approval and CSA certification for use in explosive atmosphere, Exd IIB GB, Extb IIIC Db, IP-67, 02
- Status lamps (green - permissive and red - non-permissive)
- It has a relay output with 02 SPDT contact channels, one normal open and one normal closed, 5a, 250vac - resistance
- 2 electrical connections of 3/4” NPT, power supply: 110v or 220v, 60hz.
- It monitors both ground and overfill permits in a single enclosure.
- The electronic circuit uses self-checking principles for all system components. In case of failure of any of the components, this reverts to a safe failure condition (NOT PERMISSIVE). The system must then be repaired and returned to its operational condition.
- If bypass mode is enabled, in the overflow condition, the green and red status lights will flash alternately.
- If the monitor does not receive a proper grounding check signal, the red status light will blink, not allowing the charging process.
Certification
- UL and INMETRO (CSE).
Accessories
- Aluminum junction box for interconnecting black coil cable and alligator clip;
- Coil cable in black color, with 5 conductors, 2M at rest and up to 12M stretched for connection to the junction box;
- Alligator claw made of aluminum for connection to the truck;
- Aluminum Junction Box with 7-pin socket for connection to the overfill sensor;
- Optical aluminum overfill sensor to be connected to the junction box to send feedback to the monitor in case of overfill detection.
Related Links
Civacon Model 8130 Optic Rack Monitor with Ground Verification from OPW-ES